GH 11 1KVA-3KVA
GH 11 1KVA-3KVA

GH 11 series is specifically designed for operation in poor power areas. They provides high power density with long backup time in compact size. It’s ideal for ATMs, banking and other business critical applications.

Scudo 400VA/600VA Standby UPS

o    True double-conversion

o    Microprocessor control optimizes reliability

o    Input power factor correction

o    Output power factor 0.8

o    Wide input voltage (110 V – 300 V)

o    Converter mode available

o    ECO mode for energy saving

o    Generator compatible

o    Charger capacity expansion to 6A for long-run models

o    Smart SNMP works well with either USB or RS-232 together

o    Comprehensive display allows easy monitoring and access of UPS status




Model

GH 11 1K (L)

GH 11 2K (L)

GH 11 3K (L)

Phase

Single phase with ground

Capacity

1000 VA/800 W

2000VA/1600 W

3000VA/2400 W

Input

Nominal Voltage

100/110/115/120/127VAC or   200/208/220/230/240VAC


Input Voltage Range

55-150 VAC or 110-300 VAC(Based on load at 50%)
    85-140 VAC or 160-280 VAC(Based on load at 100%)

Frequency Range

40Hz ~ 70 Hz

Power Factor

≧0.99 @ Nominall Voltage (100% load)

Output

Output Voltage

100/110/115/120/127VAC  or 200/208/220/230/240VAC

Voltage Requlation

± 1%

Frequency Range (Synchronized Range)

47~ 53 Hz or 57 ~ 63 Hz

Frequency Range (Batt. Mode)

50 Hz or 60Hz ± 0.1 Hz

Current Crest Ratio

3:1

Harmonic Distortion

≦ 3 % THD (Linear Load) ; ≦ 6 % THD (Non-linear Load)


Transfer Time

AC to DC

Zero

Inverter to Bypass

4 ms (Typical)

Waveform (Batt. Mode)

Pure Sinewave

Efficiency

To AC Mode

88%

88%

90%

To Battery Mode

83%

85%

88%

Battery






Standard Model

Battery   Type

12 V / 9 AH

12 V / 9 AH

12 V / 9 AH

Numbers

2

4

6

Typical   Recharge Time


      4 hours recover to 90% capacity

Charging     Current(Max.)


                   1.0   A

Charging   Voltage

27.4VDC   ± 1%

54.7   VDC ±1%

82.1   VDC ±1%



Long-run Model *(Only for 200/208/230/240VAC systems)

Battery     Type

Depending on the capacity of external batteries

Numbers

2

3

4

6

6

8

Charging   Current(max.)


           1.0A/2.0A/4.0A/6.0     A

Charging   Voltage

27.4VDC   ± 1%

41.0VDC   ±1%

54.7VDC±1%

82.1VDC ±1%

82.1 VDC ±1%

109.4VDC   ±1%

INDICATORS

LCD Display

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARM

Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continously sounding

Physical


Standard Model

Dimension, DxWxH (mm)

282 x 145 x 220

397 x 145 x 220

421 x 190 x 318

Net   Weight(kgs)

9.8

17

27.6

Long-run     Model

Dimension, DxWxH (mm)

282 x 145 x 220

397 x 145 x 220

Net   Weight(kgs)

4.1

6.8

7.4

Environment

Humidity

20-90% RH @ 0- 40°C (Non-condensing)

Noise Level

Less than 50dBA @ 1 Meter

Managerment

Smart RS-232/USB

Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser

*Long-run model is only available in 200/208/220/230/240VAC systems.


**Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC.

pProduct specifications are subject to change without further notice