GH 11 6KVA-10KVA
GH 11 6KVA-10KVA

GH 11 6kva 10kva ups is specifically designed for operation in poor power areas. They provides high power density with long backup time in compact size. It’s ideal for ATMs, banking and other business critical applications.

Scudo 400VA/600VA Standby UPS
Scudo 400VA/600VA Standby UPS

o    True double-conversion online UPS

o    DSP technology guarantees high performance

o    Output power factor 0.8

o    Standard backup UPS and long backup UPS in one integrated unit

o    Adjustable charging current via LCD or software (0.5A~6A)

o    Wide input voltage range (110-300 VAC)

o    Active input power factor correction 0.99

o    50Hz/60Hz frequency converter mode

o    Emergency power off function (EPO)

o    3-stage extendable charging design for optimized battery performance

o    Maintenance bypass available

o    SNMP/USB/RS-232 communications

 


Model

GH 11 6K(L)

GH 11 10K(L)

Phase

Single phase with ground

Capacity

6000 VA / 4800 W

10000VA / 8000 W

Input

Nominal Voltage

208/220/230/240VAC

Voltage Range

176-300VAC at 100% Load ; 110-300 VAC at 50% Load

Frequency Range

46Hz ~ 54 Hz or 56Hz ~ 64 Hz

Power Factor

≧ 0.99 @ 100% Load

Output

Output Voltage

208/220/230/240VAC

Output Voltage Regulation

±1%

Frequency Range (Synchronized Range)

46Hz ~ 54 Hz or 56Hz ~ 64 Hz

Frequency Range(Batt.Mode)

50 Hz ± 0.1 Hz or 60 Hz ±0.1 Hz

Current Crest Ratio

3:1(max.)

Harmonic Distortion

≦3 % THD (Linear Load),
  ≦6 % THD (Non-linear Load)

≦3 % THD (Linear Load),
  ≦6 % THD (Non-linear Load)

Transfer   Time

Bypass to Inverter (Line mode)

Zero

Inverter to Bypass (Line mode)

Zero

Waveform (Batt. Mode)

Pure Sinewave

Efficiency

Line Mode

89%

90%

Battery Mode

88%

89%

Battery

Standard   Model

Battery  Type

12 V / 9 AH

12 V / 9 AH

 

Numbers

16pcs

16pcs

Typical   Recharge Time

9 hours   recover to 90% capacity

9 hours recover to 90% capacity

Charging

Current

Default:1.0A ± 10%, Max.:2.0A ± 10%

Default:1.0A ± 10%, Max.:2.0A ± 10%

Float   Charging Voltage

218.4 VDC ± 1%

218.4 VDC ± 1%

Long-run   Model

Battery  Type

Depending on applications

Numbers

16-20(Adjustable)

Charging   Current

Default:4.0A ± 10%, Max.:6.0A ± 10%

Default:4.0A ± 10%, Max.:6.0A ± 10%

Float   Charging Voltage

273 VDC ± 1% (based on 20 pcs batteries)

Indicators

LCD Display

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

Alarm

Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continuously sounding

Physical

Standard   Model

Dimension,DxWxH(mm)

369 * 190 * 688

442 * 190 * 688

Net Weight (kgs)

60

75

Long-run Model

Dimension,DxWxH(mm)

369 * 190 * 318

442 * 190 * 318

Net Weight(kgs)

21

23

Environment

Operation Humidity

0-95% RH @ 0- 40°C (Non-condensing)

Noise Level

Less than 55dBA @ 1 Meter

Less than 58dBA @ 1 Meter

Managerment

Smart RS-232/USB

Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser

  

* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage   is adjusted to 208VAC.

 

* If the UPS is installed or used in a place where the altitude is above than   1000m, the output power must be derated one percent per 100m.

 

* Product specifications are subject to change without further notice.