GH 33 10KVA-30KVA
GH 33 10KVA-30KVA

Designed in small footprints, GH 33 online series integrates true double conversion design, DSP technology, and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all time.

Scudo 400VA/600VA Standby UPS
Scudo 400VA/600VA Standby UPS
Scudo 400VA/600VA Standby UPS

o    True double-conversion

o    DSP technology guarantees high performance

o    Output power factor 0.8

o    Wide input voltage range (110-300 VAC)

o    Active power factor correction in all phases

o    50Hz/60Hz frequency converter mode

o    ECO mode operation for energy saving

o    Accepts dual-mains inputs

o    Emergency power off function (EPO)

o    Generator compatible

o    SNMP+USB+RS-232 multiple communications

o    3-stage extendable charging design for optimized battery performance

o    Adjustable battery numbers

o    Maintenance bypass available

o    Optional N+X parallel redundancy

o    Optional isolation transformer offers full isolation and complete common mode noise rejection

 


Model

GH 3/3-10K (L)

GH 3/3-15K (L)

GH 3/3-20K (L)

GH 3/3-30K (L)

Phase

3-phase  in / 3-phase out

Capacity

10000 VA / 8000 W

15000 VA / 12000 W

20000 VA / 16000 W

30000 VA / 24000 W

Input

Nominal Voltage

3 x   400 VAC (3Ph+N)

Input Voltage Range

305-478 VAC (3-phase) at 100% load ; 190-520 VAC (3-phase) at 50% load

Frequency Range

46~54 Hz or 56~64Hz

Power Factor

≧ 0.99 @ 100% Load

Output

Output Voltage

3 x 400 VAC (3Ph+N)

AC Voltage Regulation (Batt. Mode)

± 1%

Frequency Range (Synchronized Range)

46~54Hz or 56~64Hz

Frequency Range (Batt. Mode)

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

Current Crest Ratio

3:1(max.)

Harmonic Distortion

≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)

Transfer   Time

AC Mode to Batt. Mode

Zero

Inverter to Bypass

Zero

Waveform (Batt. Mode)

Pure Sinewave

EFFICIENCY

AC Mode

89%

89%

89%

90%

Battery   Mode

86%

88%

87%

89%

Battery

Standard   Model

Battery Type

12 V / 9 Ah

Numbers

20pcs (18 - 20 adjustable)*

20pcs x 2 strings (18 - 20 adjustable)*

20pcs x 3 strings(18-20 adjustable)*

Typical   Recharge Time

9 hours recover to 90% capacity

Charging   Current (Max.)

1A

2A

2A

4A

Charging   Voltage

273 VDC ± 1%

Long-run   Model

Battery   Type

Depending on the capacity of external batteries

Numbers


Charging   Current (Max.)

4A

4A

4A

12A

Charging   Voltage

273 VDC ± 1%

Indicators

LCD   Display

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and   Fault

Alarm

Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continously sounding

Physical

Standard   Model

Dimension,DxWxH 

815 x 250 x 826

815 x 250 x 826

815 x 250 x 826

815 x 300 x 1000

Net Weight (kgs)

109

164

164

233.5

Long-run   Model

Dimension, DxWxH 

592 x 250 x 826

592 x 250 x 826

592 x 250 x 826

815 x 250 x 826

Net Weight (kgs)

38

40

40

64

Envoronment

Humidity

0-95% RH @ 0- 40°C (Non-condensing)

Noise Level

Less than 60dB @ 1 Meter

Less than 65dB @ 1 Meter

Managerment

Smart RS-232/USB

Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser

 

 

*   Derate capacity to 90% when the output voltage is adjusted to 208VAC.

*  When using internal batteries from 18-19, the unit will de-rate according to the   below formula: P = Prating X N/20 

*  Product specifications are subject to change without further notice