GR 31 10KVA-20KVA
GR 31 10KVA-20KVA

This industrial-grade online series integrates true double conversion design and DSP technology to guarantee best output voltage conditions, power quality and power performance at all times for sensitive loads in distributed data centers.

Scudo 400VA/600VA Standby UPS
Scudo 400VA/600VA Standby UPS
Scudo 400VA/600VA Standby UPS

o    True double-conversion

o    DSP technology guarantees high performance

o    Output power factor 0.8

o    Wide input voltage range (110-300 VAC)

o    Active power factor correction in all phases

o    Built-in phase auto adapt function simplifies wire installation

o    50Hz/60Hz frequency converter mode

o    Eco mode operation for energy saving (ECO)

o    Emergency power off function (EPO)

o    Generator compatible

o    SNMP+USB+RS-232 multiple communications

o    3-stage extendable charging design for optimized battery performance

o    Adjustable battery numbers

o    Optional N+X parallel redundancy



Model

GR

   3/1-10KR (L)

GR

  3/1-15KR(L)

GR

  3/1-20KR(L)

Phase

3-phase in / 1-phase out

Capacity

10000 VA/8000 W

15000 VA/12000 W

20000 VA / 16000 W

Input

Nominal Voltage

3 x 400 VAC (3Ph+N)

Voltage Range

305-478 VAC (3-phase) at 100% load ; 190-520 VAC     (3-phase) at 50% load

Frequency Range

46~54 Hz or 56~64Hz

Power Factor

≧ 0.99 @ 100% Load

THDi

< 6% @ 100% Load

Output

Output Voltage

208/220/230/240VAC

AC Voltage Regulation (Batt. Mode)

±1%

Frequency Range (Synchronized Range)

46~54Hz or 56~64Hz

Frequency Range (Batt. Mode)

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

Current Crest Ratio

3:1

Harmonic Distortion

≦2 % THD (Linear Load) ; ≦ 5% THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode

Zero

Inverter to Bypass

Zero

Waveform  (Batt. Mode)

Pure Sinewave

Efficiency

AC Mode

89%

Battery Mode

86%

88%

87%

Battery

Standard Model

Battery Type

12 V / 9 Ah

Numbers

20 (18 - 20 adjustable)

20 pcs x 2 strings (18 - 20 adjustable)

Typical Recharge Time

9 hours recover to 90% capacity

Charging Current (Max.)

1A

2A

Charging Voltage

273 VDC ± 1% (based on battery numbers at 20 pcs)

Long-run Model

Battery Type

Depending on the capacity of external batteries

Numbers

Charging Current (Max.)

4A

Charging Voltage

273 VDC ± 1% (based on battery numbers at 20 pcs)

Indicators

LCD Display

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

Alarm

Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continously sounding

Physical

Standard Model

Dimension, DxWxH (mm)

UPS unit:668 x 438 x 133(3U) 
 Battery pack: 580 x 438 x 133(3U)

UPS unit:668x438x266(6U) 
Battery pack: 580x438x133(3U)x2PCS

Net Weight (kgs)

UPS unit: 22 
   Battery pack: 63

UPS unit: 45 
    Battery pack: 63 x 2PCS

Long-run Model

Dimension, DxWxH (mm)

668 x 438 x 133(3U)

668 x 438 x 266(6U)

Net     Weight (kgs)

22

45

Environment

Operation Humidity

0-95% RH @ 0- 40°C (Non-condensing)

Noise Level

Less than 60dB @ 1 Meter

Less than 65dB @ 1 Meter

Managerment

Smart RS-232/USB

Supports Windows® 2000/2003/XP/Vista/2008,     Windows® 7/8, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser

 

*     L means long-run model

 

*     Product specifications are subject to change without further notice